IEC Hazardous Area Brake Motors

IEC Hazardous Area Brake Motors

E..DB / E..DC & E..HB / E..HC Motors 

  • Flameproof Motors – Ex db enclosure with separate Ex db brake.

  • Compliance – Meets IEC/EN 60079, IEC 60034, and IEC 60072 standards.

  • Explosion Protection – ATEX II2G, II2D, II2GD; Gas groups IIB, IIC; Dust groups IIIB, IIIC.

  • Temperature Ratings – Classes T3 to T6; Surface temperatures from T150°C to T85°C.

  • Ingress Protection – IP55, IP56, IP65, IP66.

  • Frame Sizes – 80 to 315 (IEC).

  • Power Range – 0.75 – 200 kW.

  • Voltage & Frequency – 400V/50Hz (multi-voltage options available).

  • Cooling Types – IC416 (forced cooling), IC410 (non-ventilated), IC411 (self-cooling).

  • Efficiency Ratings – IE3 (Premium), IE4 (Super-Premium), IE1/IE2 available.

Facebook
Twitter
LinkedIn

E..DB / E..DC IE3-IE4

  • Ex db, Ex db eb, Ex tb, Ex tc
  • ATEX category II2G, II2D, II2GD
  • Gas group IIB, IIC
  • Dust group IIIB, IIIC
  • Temperature classes T3, T4, T5, T6
  • Surface temperature classes (Dust) T150°C – T135°C – T125°C – T100°C – T85°C
  • Protection IP55, IP56, IP65, IP66
  • Frame size from 80 to 315 (IEC)
  • Power 0,75 – 200 kW
  • 400V/50Hz (multi voltage 380-400-420V/50Hz and 460V/60Hz)
  • Pole 2, 4, 6, 8 and dual speed motor (separate windings or Dahlander)
  • Special execution available up to -60/+80°C
  • Forced cooling (IC416); Not ventilated (IC410)
  • Premium efficiency IE3; Super-premium efficiency IE4; Available IE1/IE2
  • Certified ATEX and IECEx
  • Certified GMEE

E..HB / E..HC IE3-IE4

  • Ex db, Ex db eb, Ex tb, Ex tc
  • ATEX category II2G, II2D, II2GD
  • Gas group IIB, IIC
  • Dust group IIIB, IIIC
  • Temperature classes T3, T4, T5, T6
  • Surface temperature classes (Dust) T150°C – T135°C – T125°C – T100°C – T85°C
  • Protection IP55, IP56, IP65, IP66
  • Frame size from 80 to 315 (IEC)
  • Power 0,75 – 200 kW
  • 400V/50Hz (multi voltage 380-400-420V/50Hz and 460V/60Hz)
  • Pole 2, 4, 6, 8 and dual speed motor (separate windings or Dahlander)
  • Special execution available up to -60/+80°C
  • Self-cooling (IC411)
  • Premium efficiency IE3; Super-premium efficiency IE4; Available IE1/IE2
  • Certified ATEX and IECEx
  • Certified GMEE